❄️ BTU/hr to Kilowatts Converter
Professional HVAC Power Calculator | Air Conditioning & Heating Tool
📊 Common HVAC Capacities
📚 Complete Guide to BTU/hr and Kilowatts Conversion
Understanding BTU per Hour and Kilowatts
BTU per hour (BTU/hr or Btu/h) measures the rate of heat energy transfer, expressing how much thermal energy a heating or cooling system can move in one hour. One British Thermal Unit (BTU) is the amount of energy needed to heat one pound of water by one degree Fahrenheit at sea level. BTU/hr is the standard power measurement in the United States HVAC industry for air conditioners, furnaces, heaters, boilers, and heat pumps. Kilowatts (kW) are the International System of Units (SI) standard for measuring power, representing the rate of energy transfer in the metric system. One kilowatt equals 1,000 watts or 1,000 joules per second. The exact conversion factor is: 1 BTU/hr = 0.000293071 kilowatts, which can also be expressed as: 1 kW = 3,412.142 BTU/hr. This conversion is essential for comparing HVAC equipment specifications internationally, calculating electricity consumption costs, sizing heating and cooling systems, understanding energy efficiency ratings, and converting between Imperial and metric power measurements in engineering and construction applications.
The Conversion Formula
To convert BTU/hr to kilowatts: kW = BTU/hr × 0.000293071 or kW = BTU/hr ÷ 3412.142. Both formulas produce identical results. Multiply your BTU/hr value by 0.000293071 for exact kilowatt conversion. Examples: 5,000 BTU/hr = 1.47 kW; 10,000 BTU/hr = 2.93 kW; 12,000 BTU/hr = 3.52 kW; 18,000 BTU/hr = 5.28 kW; 24,000 BTU/hr = 7.03 kW; 36,000 BTU/hr = 10.55 kW. To convert kilowatts to BTU/hr: BTU/hr = kW × 3412.142 or BTU/hr = kW ÷ 0.000293071. Multiply kilowatts by 3412.142 for BTU/hr conversion. Examples: 1 kW = 3,412 BTU/hr; 2 kW = 6,824 BTU/hr; 3.5 kW = 11,942 BTU/hr; 5 kW = 17,061 BTU/hr; 10 kW = 34,121 BTU/hr. These conversions are critical for HVAC technicians sizing equipment, homeowners comparing air conditioner specifications, engineers designing building climate control systems, and energy auditors calculating heating/cooling loads and electrical consumption for residential and commercial applications.
Common Conversions
| BTU per Hour | Kilowatts (kW) | Typical Application |
|---|---|---|
| 5,000 BTU/hr | 1.47 kW | Small window AC (150-250 sq ft) |
| 6,000 BTU/hr | 1.76 kW | Window AC (250-300 sq ft) |
| 8,000 BTU/hr | 2.34 kW | Window AC (300-350 sq ft) |
| 10,000 BTU/hr | 2.93 kW | Window AC (400-450 sq ft) |
| 12,000 BTU/hr | 3.52 kW | 1-Ton AC (450-550 sq ft) |
| 15,000 BTU/hr | 4.40 kW | Large window AC (600-700 sq ft) |
| 18,000 BTU/hr | 5.28 kW | 1.5-Ton AC (700-1000 sq ft) |
| 24,000 BTU/hr | 7.03 kW | 2-Ton AC (1000-1200 sq ft) |
| 36,000 BTU/hr | 10.55 kW | 3-Ton AC (1500-2000 sq ft) |
| 48,000 BTU/hr | 14.07 kW | 4-Ton AC (2000-2500 sq ft) |
Air Conditioner Sizing Applications
BTU/hr-to-kW conversions are fundamental for residential and commercial air conditioning selection. Room Air Conditioners: Window and portable AC units are rated in BTU/hr in the US market (5,000-24,000 BTU/hr typical), but electrical specifications and energy consumption use kilowatts. A 12,000 BTU/hr window unit (3.52 kW cooling capacity) typically consumes 1.0-1.2 kW electrical power depending on efficiency. Understanding both ratings helps homeowners calculate electricity costs and select appropriately sized units. Central Air Conditioning: Whole-house systems use "tons" of cooling (1 ton = 12,000 BTU/hr = 3.52 kW). A 3-ton central AC (36,000 BTU/hr or 10.55 kW) suits homes 1,500-2,000 square feet with standard insulation. Converting to kW helps compare with heat pump specifications, which increasingly use metric ratings, and enables accurate electrical load calculations for circuit breaker and wire sizing in residential electrical panels.
Heating System Specifications
Furnaces, boilers, and heaters use BTU/hr ratings requiring conversion for electrical and efficiency analysis. Gas Furnaces: Residential gas furnaces typically range from 40,000-120,000 BTU/hr (11.7-35.2 kW) heating capacity. While the primary fuel is natural gas, blower fans and controls consume electrical power (400-800 watts or 0.4-0.8 kW), requiring circuit planning. Converting total heating capacity to kW enables comparison with electric heat pumps and resistance heaters for lifecycle cost analysis. Electric Heaters: Electric resistance heaters and baseboard heaters have 1:1 efficiency, meaning 1 kW electrical input produces 3,412 BTU/hr heat output. A 5 kW electric heater delivers 17,061 BTU/hr—understanding this conversion helps homeowners compare electric heating costs with gas furnace operation, where natural gas energy content and combustion efficiency affect BTU/hr output per unit of fuel consumed.
Energy Efficiency Calculations
HVAC efficiency ratings require BTU/hr and kW conversions for meaningful comparisons. SEER Ratings: Seasonal Energy Efficiency Ratio (SEER) measures air conditioner efficiency in BTU/hr per watt. A 16 SEER air conditioner produces 16 BTU/hr of cooling per watt of electricity consumed. Converting: a 12,000 BTU/hr (3.52 kW) AC with 16 SEER consumes 750 watts (0.75 kW) electrical power. Higher SEER means lower electricity consumption and operating costs. EER Ratings: Energy Efficiency Ratio (EER) measures steady-state efficiency at specific temperature conditions (95°F outdoor, 80°F indoor). EER = BTU/hr output ÷ watts input. A 10 EER means 10 BTU/hr per watt. Modern AC units range from 8.5-12 EER. Converting helps calculate actual electricity costs: a 24,000 BTU/hr AC with 10 EER uses 2,400 watts (2.4 kW) electrical power continuously.
Electrical Load Planning and Circuit Sizing
Converting HVAC capacity to electrical power consumption enables proper electrical system design. Circuit Breaker Sizing: Air conditioners and heat pumps specify cooling/heating capacity in BTU/hr, but electricians need kilowatt consumption for circuit breaker selection. A 24,000 BTU/hr mini-split AC (7.03 kW cooling capacity) with 12 SEER efficiency consumes approximately 2,000 watts (2.0 kW) electrical power, requiring a dedicated 20-amp, 240-volt circuit. Startup surge current can be 2-3× running current, affecting breaker sizing. Generator Capacity: Homeowners selecting backup generators need to convert HVAC BTU/hr ratings to running wattage. A 36,000 BTU/hr central AC with 14 SEER requires approximately 2,571 watts (2.57 kW) running power. Including startup surge and other appliances, an 8-10 kW generator suits most residential applications.
HVAC Cost Calculations
Converting BTU/hr to kW enables accurate electricity cost estimation for heating and cooling. Operating Cost Analysis: Electricity is priced per kilowatt-hour (kWh). A 12,000 BTU/hr window AC consuming 1.0 kW running 8 hours daily uses 8 kWh per day. At $0.13/kWh, daily cost is $1.04 ($31.20 monthly). Accurate BTU/hr to kW conversion ensures precise cost projections. Heat Pump Economics: Modern heat pumps deliver 2-4 kW of heating (6,824-13,648 BTU/hr) for every 1 kW electricity consumed (COP 2-4), offering significant savings versus electric resistance heating (1:1 ratio, 1 kW = 3,412 BTU/hr). Converting between BTU/hr and kW helps compare heating costs: natural gas at $1.50/therm produces 100,000 BTU (29.3 kW) for $1.50, versus electric resistance at $0.13/kWh costing $3.81 for equivalent heating—understanding these conversions informs fuel choice decisions.
Understanding Different Power and Energy Units
Several related but distinct units cause confusion in HVAC applications. BTU/hr vs BTU: BTU/hr measures power (rate of energy transfer), while BTU measures total energy. A 10,000 BTU/hr air conditioner running 3 hours consumes 30,000 BTU total energy. kW vs kWh: Kilowatts (kW) measure instantaneous power, while kilowatt-hours (kWh) measure total energy consumption. A 2 kW heater running 5 hours consumes 10 kWh energy. Electricity bills charge per kWh, not kW. Thermal Power vs Electrical Power: HVAC equipment BTU/hr ratings specify thermal (heating/cooling) capacity. Electrical power consumption is different—a 24,000 BTU/hr (7.03 kW thermal) AC might consume only 2.0 kW electrical power thanks to refrigeration cycle efficiency. Always distinguish between thermal capacity and electrical consumption when converting units.
Quick Mental Conversion Tips
Simple Approximation: Remember that 3,400 BTU/hr ≈ 1 kW (exact: 3,412.142) for quick estimates. Divide BTU/hr by 3,400 to approximate kW. Common Benchmarks: 12,000 BTU/hr = 3.5 kW (1 ton AC); 24,000 BTU/hr = 7 kW (2 tons); 36,000 BTU/hr = 10.5 kW (3 tons). Reverse Approximation: Multiply kW by 3,400 to estimate BTU/hr. Example: 5 kW × 3,400 = 17,000 BTU/hr (exact: 17,061). Energy Cost Rule: 1 kW running continuously for 1 hour = 1 kWh ≈ 3,412 BTU energy delivered. At $0.13/kWh, 1 kW costs $0.13 per hour to operate. For precise engineering calculations, energy audits, contractor estimates, and equipment selection, always use exact conversion factors (0.000293071 or 3412.142) rather than approximations to ensure accuracy in HVAC system design, electrical planning, and cost projections for residential and commercial applications.
Why Choose RevisionTown's Converter?
RevisionTown's advanced BTU/hr to kW converter provides: (1) Exact Precision—Uses the internationally standardized conversion factor 0.000293071; (2) Bidirectional Conversion—Seamlessly convert BTU/hr↔kW with dedicated tabs; (3) Bulk Processing—Convert multiple HVAC unit capacities simultaneously; (4) Quick Reference—Instant access to common air conditioner and heating system ratings; (5) Formula Transparency—View exact mathematical formulas for verification; (6) Mobile Optimized—Use on smartphones at job sites, showrooms, and homes; (7) Zero Cost—Completely free with no registration; (8) Professional Accuracy—Trusted by HVAC technicians, contractors, engineers, energy auditors, and homeowners for critical power conversions in air conditioner selection, heating system sizing, energy efficiency calculations, electrical load planning, cost analysis, and HVAC equipment specifications requiring exact translations between Imperial BTU/hr and metric kilowatt measurements for residential, commercial, and industrial climate control applications.
❓ Frequently Asked Questions
One BTU per hour equals exactly 0.000293071 kilowatts. Formula: 1 BTU/hr = 0.000293071 kW. This is the internationally standardized conversion factor for power measurement between Imperial and metric systems used in HVAC applications.
Multiply by 0.000293071 or divide by 3412.142. Formula: kW = BTU/hr × 0.000293071 or kW = BTU/hr ÷ 3412.142. Examples: 5,000 BTU/hr = 1.47 kW; 10,000 BTU/hr = 2.93 kW; 12,000 BTU/hr = 3.52 kW; 24,000 BTU/hr = 7.03 kW. This conversion is essential for HVAC and air conditioning specifications.
12,000 BTU/hr equals 3.52 kilowatts. Calculation: 12,000 × 0.000293071 = 3.52 kW. This is a standard 1-ton air conditioner capacity, commonly used in residential cooling applications for rooms 400-550 square feet with standard insulation and moderate sun exposure.
One kilowatt equals 3,412.142 BTU per hour. Calculation: 1 kW × 3412.142 = 3,412.142 BTU/hr. This conversion helps translate metric power ratings to Imperial HVAC specifications commonly used in the US market for heating and cooling equipment.
Multiply by 3412.142 or divide by 0.000293071. Formula: BTU/hr = kW × 3412.142. Examples: 1 kW = 3,412 BTU/hr; 2 kW = 6,824 BTU/hr; 3.5 kW = 11,942 BTU/hr; 5 kW = 17,061 BTU/hr; 10 kW = 34,121 BTU/hr.
2.5 kilowatts equals approximately 8,530 BTU/hr. Calculation: 2.5 kW × 3412.142 = 8,530 BTU/hr. This is slightly smaller than a standard 9,000 BTU window unit, suitable for rooms 250-350 square feet with moderate insulation and sun exposure. Consider room size, insulation, ceiling height, and sun exposure when selecting capacity.
HVAC systems in the United States traditionally use BTU/hr because the US customary system historically dominated American engineering and construction. BTU directly relates to heat energy transfer in heating and cooling applications, making it intuitive for thermal calculations. However, international markets and electric heat pumps increasingly use kilowatts for consistency with electrical power ratings. Modern energy efficiency standards (SEER, EER) bridge both systems.
A 24,000 BTU/hr air conditioner equals 7.03 kilowatts cooling capacity. Calculation: 24,000 × 0.000293071 = 7.03 kW. This is a 2-ton air conditioning unit, commonly used for larger rooms (800-1,200 sq ft) or small commercial spaces. Note this is cooling capacity, not electrical power consumption—actual electricity use depends on efficiency rating (SEER/EER).